『Burkert Flow Meter: Sourcing German Precision Fluid Control Valves』Related information(clamp on meter|electromagnetic meter|venturi meterrotameter|orifice meter|ultrasonic flow meter|mass flow meter|coriolis mass flow meter|coriolis flow meter|magnetic flow meter|magmeter flow meter|magflow flow meter|mag meter flow meter|electromagnetic flow meter|vortex flow meter|turbine flow meter|thermal mass flow meter|thermal flow meter|rotameter flow meter)

Burkert Flow Meter: Sourcing German Precision Fluid Control Valves
Quick Answer
Burkert flow meters and fluid control valves are built for repeatable dosing, batching, and monitoring in harsh process environments. Silver Automation Instruments supplies original Burkert electromagnetic meters, paddle wheel sensors, thermal mass meters, and pneumatic angle seat valves with full factory warranty. Tell us your medium, pipe size, and pressure range and you get a solid quotation the same working day.
Many engineers skip the brand comparison and go straight to a Burkert 8045 electromagnetic meter when they need a meter that holds calibration on a CIP return line with hot caustic. That is what we see in dairy plants across New Zealand and in water treatment sites in Saudi Arabia. The device body has no moving parts, handles conductivity down to 20 µS/cm, and outputs 4-20 mA, pulse, or HART 7 with a built-in PT1000 temperature sensor. You can order it in DN06 up to DN400, with Tri-Clamp, weld-on, or flanged connections. We help you pick the liner material for your chemistry: PFA for aggressive acids, hard rubber for abrasive slurry. In practice, most customers in Southeast Asia take the 8045 with a compact transmitter and local display because it removes the need for a separate controller on small skids.
For ultrapure water loops and demineralized water batching, a Burkert 8035 inline paddle wheel flow meter often makes more sense than an electromagnetic meter. It does not require a minimum conductivity and works straight on 18.2 MΩ·cm water at 25 °C. A semiconductor parts washer in Malaysia used six units of 8035 with polypropylene bodies and Hastelloy axles to monitor rinse water flow. We supplied the meters preset to 4-20 mA for 0 to 60 L/min, no local display, because the PLC already handled the scaling. The plant saved panel space and avoided air bubble drift issues they had with competitive ultrasonic clamp-on meters. That is the kind of detail we ask upfront: Do you need a display, do you want pulse output for a batch controller, and what is your pipe ID in mm, not just nominal DN.
When process temperature climbs past 130 °C or the fluid is a sticky heat transfer oil, the conversation moves to Burkert control valves and thermal mass meters. A paint manufacturer in Thailand operates a jacketed 2100 series angle seat valve on a reactor discharge line flowing 1.8 cP solvent at 4 bar and 140 °C. They needed a valve with a PTFE seat, an NC pneumatic actuator, and a Type 8692 digital positioner to get position feedback over Profibus DP. Silver Instruments sourced the complete assembly and a matching Burkert 8700 thermal mass flow meter for the nitrogen blanket line. We pre-checked the I/P calibration sheet and shipped the valve with a 3.1 material certificate, which the plant QA team requested. If your application involves steam, hot water, or aggressive gases, we can quote the full Burkert Type 2100, 2000, or 2301 series with pilot valves, limit switches, and positioners in one package.
Here is the thing many first-time buyers miss: Burkert flow meters ship with default settings that may not match your actual pipe velocity profile. We ask for your minimum, normal, and maximum flow rate in kg/h or L/h, then we preconfigure the measuring range in the factory tool. This eliminates hours of onsite fiddling with an 8025 universal transmitter. A small edible oil refinery in Peru learned this the hard way with a turbine meter they bought from a catalogue. After switching to a Burkert 8071 turbine with a local batch controller from Silver Instruments, they cut batch overfill from 1.2 percent to 0.3 percent because the K-factor was embedded and the cut-off frequency correctly set for their 15 cP oil at 40 °C. We stock the 8071 in DN15 to DN50 and can integrate it with the 8025 batch controller or your existing PLC via pulse and 4-20 mA.
Our typical customer is a 30-person EPC contractor in Brazil putting together a chromium plating line, or a water utility in Oman retrofitting a filter building with 24 electromagnetic flow transmitters. They want a single source for the meter, the valve, the fitting, and the initial configuration not

We also pay attention to the small parts that derail a startup. A food ingredients plant in the Philippines needed a Burkert 8035 for a 10 mm OD tube. We noticed the tube wall was thinner than standard and supplied the correct PVDF adapter set with a different O-ring material. The local distributor they tried first only had 1-inch fittings and told them to use a reducer, which would have introduced flow turbulence and a measurement offset. The lesson: when you send us your exact pipe outside diameter, we match the meter to the fitting, not the other way around. If you are unsure about the fitting type, just send a photo of the pipe connection point via WeChat and we identify the thread or flange standard within an hour.
Send us your pressure (bar), temperature (°C), pipe size (DN or exact outer diameter), medium, conductivity if known, and required output signals. We will quote a complete Burkert flow meter or valve assembly with freight to your port. Reach us at Tel: +86-135-1213-1526, Whatsapp: 86-135-12131526, or WeChat: +86 13512131526.
FAQ
Which Burkert flow meter works for demineralized water with almost zero conductivity?
Use a Burkert 8035 paddle wheel flow meter. It needs no liquid conductivity and handles ultrapure water up to 18.2 MΩ·cm. Specify the polypropylene or PVDF body and the correct K-factor fitting set for your tube diameter. We can set the output to 4-20 mA or frequency pulse.
Can I get a Burkert 8045 electromagnetic flow meter with ATEX Zone 1 certification for a solvent tank farm in the Middle East?
Yes, we supply the 8045 in ATEX Zone 1 and Zone 2 configurations. You will receive the EC-type examination certificate and a calibration sheet traceable to DKD standards. Share the gas group, temperature class, and cable gland type so we confirm the correct certification code.
Do you supply Burkert control valves with a positioner pre-assembled?
We supply Type 2100, 2000, and 2301 angle seat and globe valves with Burkert 8692, 8694, or 8696 digital positioners mounted and tested. Tell us the actuator function (NC or NO), pilot pressure, and desired communication protocol. We ship the assembly with an inspection tag showing stroke time and I/P calibration.
What is the typical lead time for a Burkert 8035 flow meter in Southeast Asia?
For standard configurations with a G2 threaded process connection and a 4-20 mA output, we hold physical stock in Nanjing and can ship within 8 working days to Singapore, Jakarta, or Bangkok. Custom K-factors or special fittings add about 5 days. Air freight takes 3 to 5 days after dispatch.
Can Silver Instruments help me select between a Burkert thermal mass meter and a Coriolis meter for a reactor feed line?
We carry Burkert thermal mass meters for gas and dry air, and we also manufacture our own Coriolis mass flow meters for liquids. Send us your medium, viscosity in cP, density, and required accuracy. If the line is liquid with low gas and needs density measurement, our Coriolis meter often gives a better total cost. For pure gas flow like nitrogen or CO₂, we recommend the Burkert 8700 thermal mass meter with inline calibration.
Silver Automation Instruments supplies industrial flow meters and precision fluid control valves to process plants and system integrators worldwide. For a specific question on a Burkert 8045, 8035, 8071, or a Burkert control valve assembly, simply send a photo of the nameplate and we give you a direct replacement quote. Tel: +86-135-1213-1526, Whatsapp: 86-135-12131526, WeChat: +86 13512131526.