『Selection of glass rotor flowmeter』Related information(clamp on meter|electromagnetic meter|venturi meterrotameter|orifice meter|ultrasonic flow meter|mass flow meter|coriolis mass flow meter|coriolis flow meter|magnetic flow meter|magmeter flow meter|magflow flow meter|mag meter flow meter|electromagnetic flow meter|vortex flow meter|turbine flow meter|thermal mass flow meter|thermal flow meter|rotameter flow meter)

What is the relationship between the calibration pressure and range of a glass rotor flowmeter? The calibration pressure of a glass rotor flowmeter is positively correlated with the range, and the higher the calibration pressure, the larger the flow range. 1. Core relationship • Pressure induced turbulence determines the density of the medium: Calibration pressure directly affects the density of the gas medium (according to the ideal gas state equation PV=nRT), and changes in density will cause changes in the force on the float, thereby affecting the flow measurement range. • Range correction formula: The actual range needs to be corrected according to the calibration pressure. The formula is: $$Q_ {Actual}=Q_ {Calibration} \ times \ sqrt {\ frac {P_ {Calibration}} {P_ {Actual}} $(Q is flow rate, P is absolute pressure) 2 Parameter Corresponding Example | Calibration Pressure (MPa) | Typical Range (Air, L/min) | |----------------|---------------------------| | 0.1| 0.5-5 | | 0.6| 2-25 | | 1.0| 5-50 | 3. Operational limitations • Maximum pressure: The pressure resistance of ordinary glass rotor flow meters is ≤ 1.6MPa. If it exceeds this limit, a metal tube type should be selected. Nonlinear interval: When the pressure exceeds 30% of the calibration value, the flow indication error may be greater than 5% (please refer to the specific model manual). four When selecting gas measurement, the calibration pressure should be ≥ 1.2 times the actual working pressure of the pipeline. Liquid measurement can be ignored due to small density changes and negligible pressure effects. 2. What parameters are required for the selection of a rotor flowmeter?
1. For the selection of remote output metal tube
_600x400.jpg)
4. For the unstable pressure of the inlet medium of the rotor flowmeter, especially for gas measurement, damping structure should be selected to ensure accuracy and service life.
5. For the medium with high pressure requirements, when exceeding the standard pressure level, please choose high-pressure structure when selecting, and use HG20595-97 RF neck welded steel pipe flange for high-pressure type. If other standards are used, please indicate
6. When installing the rotor flowmeter, the verticality of the measuring tube should be ensured to be better than 5%, and a bypass should be installed for easy maintenance and cleaning without affecting production
7. The installation