『LZB flowmeter』Related information(clamp on meter|electromagnetic meter|venturi meterrotameter|orifice meter|ultrasonic flow meter|mass flow meter|coriolis mass flow meter|coriolis flow meter|magnetic flow meter|magmeter flow meter|magflow flow meter|mag meter flow meter|electromagnetic flow meter|vortex flow meter|turbine flow meter|thermal mass flow meter|thermal flow meter|rotameter flow meter)

1. The model of the Bora 1.8t air flow meter is LZB-40. By using DME relay to provide operating voltage to the air meter and heating it to a temperature 180 degrees higher than the outside, the air flow will cool the air meter (the more air, the greater the cooling), causing the resistance value of the air meter to change and affecting the current applied to the air meter. The air gauge provides a feedback voltage of 1-5 volts, and DME determines the amount of intake air and adjusts fuel injection based on the feedback voltage. Attention should be paid to the correct installation of the air flow meter when using it. It should be installed horizontally as much as possible to meet the requirements of the straight pipeline of the flow meter. The inner diameter of the flow meter should match the inner diameter of the pipeline, and all flange bolts should be tightened to prevent dripping. The instrument wiring should be correct, and if it is exposed to the sun, rain and sun protection measures should be taken to protect the compressed air flow meter. Not every air flow meter is installed in places with high vibration. However, the air flow meters installed in the compression plant and blower room must consider vibration issues. This type of vibration mainly comes from compressors and blowers, and the vibration of the machine can be transmitted to faraway places through air pipes or ducts. 2. What is the price of an electronic flowmeter?
What does the precision level of LZB-3WB flowmeter mean?
LZB-3/LZB-3WB glass rotor flowmeter is used to measure the instantaneous flow rate of single-phase non pulsating liquids and gases in pipelines.. The commonly used Ziyou instrument series flow meters are

4. Technical specifications of glass rotor flowmeter
Glass rotor flowmeter ordinary type model nominal diameter mm working pressure MPa basic error limit% range measurement range Liquid gas LZB-2 φ 2 ≤ 1 ± 4 1:10 0.4-4 mL/min 6~60 mL/min 0.6~6 10~100 1~10 16~160 Ridge lead detection 1.6~16 25~250 LZB-3 φ 3 ≤ 1 ± 4 1:10 2.5~25 40~400 4~40 60~600 Wild Forest 6~60 100~1000 10~100 160

Current position > News detail